view all (4)

Reliable softening media for use in compact systems supplied with stable municipal or well water. ECOMIX® P 12 L prevents scale and reduces minor organic impurities without the need for pre-treatment.
Volume
12
L
Max hardness level in feed water
750
ppm CaCO3
Max iron level in feed water
15
mg/L
Max manganese level in feed water
3
mg/L
Max chemical oxygen demand level in feed water
3
mg/L O2
Max ammonium level in feed water
4
mg/L
The filter material in packaging.
Technical characteristics
- Maximum operating temperature: 40 °C
- Service flow rate: 20-25 m/h
- Backwash flow rate: 10-15 m/h
- Brine (slow rinse) flow rate: 3 - 5 m/h
- Minimum bed depth: 500 mm
- Recommended bed depth: 800 mm
- Freeboard: 40% or more
- Salt consumption: 100 g/L of media
- Brine concentration: 8-10%
- Water consumption per regeneration: under 10 L/L
- Ion-exchange capacity: 40 g CaCO3/L
Feed water requirements
- Hardness: 15 mEq/L
- Iron: 15 mg/L
- Manganese: 3 mg/L
- Chemical Oxygen Demand: 20 mg O₂/L
- Ammonium: 4 mg/L
- pH: 5-9
- Maximum TDS: 4000 mg/L